Written by admin on . Posted in products

clip_image002

  1. Casing is made of aluminum alloy and have excellent features on mechanic strength , durability , light weight and smooth exterior.
  2. Impeller is made of aluminum alloy and have excellent features on mechanic strength , durability , and light weight.
  3. RB series ring compressors are designed to comply with the safety requirements of CE / cCSAus and have attained their type approval.
  4. Design per customers requirement available.
  5. Thermal protector is optional.
 

Meet CE Norm

89/336 , 73/23 , EN60204-1 , EN50081-2 , EN50082-2

Degree of protection

IP 54 (IP 55 optional)

Insulation class

F class (155 degrees centigrade)

Voltage range /

Frequency

A

50Hz

500 V

60Hz

575 V

B

50Hz

200 ~ 240 / 345 ~ 416 V

60Hz

208 ~ 275 / 380 ~ 480 V

C

50Hz

400 / 690

60Hz

460 / —

D

50Hz

1 phase 230V +- 5%

60Hz

Installation

Any aspect.

  Specification and Operation Diagram

clip_image002Blowers with 50 Hz

Model

Phase

Voltage

Hz

kW

Rated Current Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow m3/min

Noise Level dB(A) (*3)

Weight kg

RB60-5B0

3

200 ~ 240 / 345 ~ 416

50

2.20

10.8~10.9 / 6.0~6.1

+220

5.1

76

36

RB60-5B0-9

2.20

9.0~9.9 / 5.3~5.8

+200

36

RB60-6B0

3.00

13.1~13.6 / 7.4~7.7

+280

38.4

RB60-7B0

4.00

14.7~14.8 / 8.5~8.4

+340

41.5

RB60-5D0

1

230

2.20

14.9

+200

42

clip_image002Blowers with 60 Hz

Model

Phase

Voltage

Hz

kW

Rated Current Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow m3/min

Noise Level dB(A) (*3)

Weight kg

RB60-5B0

3

208 ~ 275 / 380 ~ 480

60

2.55

11.3~10.6 / 6.4~5.9

+200

6.2

78

36

RB60-5B0-9

2.55

12.2~10.9 / 6.6~6.2

+255

36

RB60-6B0

3.45

14.9~13.2 / 8.0~7.6

+270

38.4

RB60-7B0

4.60

17.2~14.7 / 9.5~8.5

+330

41.5

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.

clip_image003

clip_image002Vacuum with 50 Hz

Model

Phase

Voltage

Hz

kW

Rated Current Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow m3/min

Noise Level dB(A) (*3)

Weight kg

RB60-5B0

3

200 ~ 240 / 345 ~ 416

50

2.20

11.6~9.9 / 5.6~5.8

-230

5.1

76

36

RB60-5B0-9

2.20

8.0~9.4 / 4.5~5.3

-180

36

RB60-6B0

3.00

11.1~12.4 / 6.3~7.0

-250

38.4

RB60-7B0

4.00

11.5~12.5 / 6.7~7.2

-270

41.5

RB60-5D0

1

230

2.20

14.7

-200

42

clip_image002Vacuum with 60 Hz

Model

Phase

Voltage

Hz

kW

Rated Current Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow m3/min

Noise Level dB(A) (*3)

Weight kg

RB60-5B0

3

208 ~ 275 / 380 ~ 480

60

2.55

11.2~10.1 / 6.0~5.7

-220

6.2

78

36

RB60-5B0-9

2.55

10.2~9.8 / 5.6~5.5

-230

36

RB60-6B0

3.45

13.2~12.3 / 7.1~7.0

-270

38.4

RB60-7B0

4.60

15.3~13.2 / 8.2~7.7

-320

41.5

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.

clip_image003

   

clip_image002RB-60-5B , RB-60-6B

clip_image003

clip_image002RB-60-7B , RB-60-5D

 

clip_image004